CONVERSION KIT INSTRUCTIONS (
#OCK-S38A NAT GAS CONVERSION KIT / #OCK-S625A LP GAS CONVERSION KIT
EQUIPPED WITH SIT GAS VALVE & PILOT ASSEMBLY
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and
all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion or production of carbon monoxide may result, causing property damage, personal injury
or loss of life. The qualified service agency is responsible for proper installation of this kit. The installation is not proper and
complete until operation of the converted appliance is checked as specified in the instructions supplied with the kit. Refer to
appliance owner‟s manual or product data plate for proper inlet and manifold pressure adjustments and orifice sizing.
Kit includes:
(1) Gas Conversion Label
(1) Pilot Injector
WARNING: SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ANY ELECTRICAL POWER.
PREPARE FIREPLACE:
1.
Turn fireplace off by pushing in and turning gas control knob clockwise to OFF position.
2.
Remove upper hood, upper louver and glass assembly*.
3.
Remove logs from fireplace.
4.
IF CONVERTING TO NAT GAS: Remove LP log plate (if installed).
5.
Remove pilot shield.
6.
Remove burner tube from fireplace.
REPLACE BURNER ORIFICE:
1.
Remove existing orifice cap. Install orifice cap included with kit, making sure to
tighten cap securely.
CONVERT PILOT ASSEMBLY:
1.
Follow instruction sheet included with kit to convert pilot to either Nat. or LP.
CONVERT GAS VALVE:
1.
Follow instructions included with kit to convert gas valve to either Nat. or LP.
COMPLETE THE CONVERSION:
1.
Adjust venturi on burner tube to correct setting by loosening screw, adjusting cap
and retightening screw. CORRECT SETTINGS: NAT. : 1/8" (3mm) open
2.
Re-install burner tube into fireplace, checking to ensure burner venturi is properly
seated over burner orifice.
4.
IF CONVERTING TO LP GAS: Install LP log plate (included with log set).
When properly seated, log plate sits between back log brackets and burner heat
shield.
5.
Re-install pilot shield.
6.
Re-install logs*.
6.
Light pilot and turn burner on*.
7.
Check for leaks at all connections, whether field or factory made.
8.
Test both inlet and manifold pressures*.
(1) Burner Orifice: NAT #38 / LP #.0625
(1) Valve Conversion Instruction Sheet
L.P. : 5/8" (16mm) open
PAGE 58
56701 units only)
(1) Gas Label
(1) Pilot Assembly Conversion Instructions
BURNER TUBE
PILOT SHIELD
Figure 58a
LP PLATE
PILOT ASSEMBLY
BURNER ORIFICE
PROPER BURNER TUBE VENTURI /ORIFICE
PLACEMENT
Figure 58b