Control Board Installation - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

CONTROL BOARD INSTALLATION

WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER CONTROL BOARD) IN
PLACE. IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
NOTE: Illustrations shown with 56701 valve components.
1. Place control board in firebox, aligning holes in control board with
holes in firebox bottom. MAKE SURE SEALING GASKET IS IN
PLACE ON FIREBOX BOTTOM! Secure to firebox bottom with
(6) screws previously removed.
2. Install log grate / burner heat shield assembly into fireplace, making
sure entire assembly (front flange) is inside firebox when completed.
3. Reinstall front log supports, securing with screws previously
removed.
4. Reinstall burner tube, sliding venturi over control board orifice,
placing mounting holes in burner tube over tabs on log grate/burner
heat shield assembly.
LP Gas Models: Reinstall LP log plate.
5. Reinstall pilot shield.
6. Reinstall refractory panels, if previously removed.
7. Reinstall bottom refractory panels.
8. Reinstall log set. (Page 28-29).
9. Reconnect gas line to manual shut-off valve.
10.Model 56701: Reconnect any wall switch, remote control or
thermostat wires to top & bottom terminals on gas valve.
Model 56701-IPI:
Re-connect all wiring harnesses to gas valve. Plug all components
into electrical outlet.
11. Reinstall glass frame assembly. Page 12.
12. Reinstall upper louver, upper hood and lower grill. Page
13. Turn gas on.
14. Verify proper log placement, operation of fireplace, and any
electrical components.
CAUTION: CHECK ALL CONNECTIONS FOR LEAKS, WHETHER FIELD OR FACTORY MADE.
LOG GRATE / BURNER HEAT SHIELD
BURNER TUBE
RE-CONNECT REMOTE / THERMOSTAT WIRES
32.
Figure 31a
PAGE 31
FRONT LOG SUPPORTS
PILOT SHIELD