VENTING (Top vent conversion instructions)
REMOVE BACK VENT COLLARS
NOTE: All components removed from fireplace back vent will be re-installed for top venting.
1
Figure 16a
1.
Remove back cover and attachment screw .
2.
Remove 6-5/8 combustion air intake collar and (4) screws.
3.
Remove 4" exhaust collar and (6) screws.
REMOVE TOP COMBUSTION AIR INTAKE & EXHAUST COLLARS
1
4
Figure 16b
1.
Remove top cover and screw.
2.
Remove heat shield cover (w/ knockout) and screw.
3.
Using tin snips, remove center knockout section
4.
Remove 6-5/8" combustion air intake cover and (4) screws.
5.
Remove exhaust cover and (6) screws.
2
2
5
.
PAGE 16
3
3
Remove