NOTE: Horizontal sections require 1/4" (6 mm) rise for every 12" (305 mm) of travel.
NOTE: Flange on top stand-off must be bent upwards to a 90˚ angle when top venting.
NOTE: Page 22 has information on restrictor installation in conjunction with venting installation. Page 51 has information on
restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed.
IMPORTANT: If top venting, follow instructions on pages 16-17 to convert fireplace from rear vent ready to top vent ready
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
HORIZONTAL TERMINATIONS (top vent)
Figure 19a
HORIZONTAL TERMINATIONS (rear vent)
Figure 19b
VENTING
Max: 14 ft. (4.27m)
Min: 6" (152 mm)
90° ELBOW
Min: 6" (152 mm)
Max: 24" (610 mm)
PAGE 19
TERMINATION CAP
TERMINATION CAP
.