Gas Line Connection - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

GAS CONVERSION
This fireplace is manufactured for use with Natural Gas. An LP conversion kit, is included with this fireplace. Follow instructions included
with conversion kit if converting to LP gas.
ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and
in accordance with the requirements of the ANSI Z223.1 installation code.
CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.
If not, follow ANSI 223.1.
Commonwealth of Massachusetts: Installation must be done by a licensed plumber of gas fitter.
NOTE: A listed (and Commonwealth of Massachusetts approved) 12" (13 mm) T- handle manual shut-off valve and flexible gas
connector (included) are connected to the 1/2" (13 mm) control valve inlet. If substituting for these components, please
consult local codes for compliance.
NOTE: This fireplace is equipped with a 3/8"(10 mm) x 18" (457 mm) long flexible gas connector and manual shut-off valve. The
gas line should be run to the point of connection where the shut-off valve and flexible gas line will connect.
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during
any pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).
NOTE: For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating
methods.
IMPORTANT: The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.
MINIMUM INLET GAS PRESSURE
MAXIMUM INLET GAS PRESSURE
MANIFOLD PRESSURE (HI)
MANIFOLD PRESSURE (LO)
ORIFICE SIZE
INPUT BTU/hr.
MINIMUM INPUT BTU/hr.
EFFICIENCY

GAS LINE CONNECTION

56701
NATURAL GAS
5.0 inches W.C.
(7.0 W.C. recommended)
10.5 inches W.C.
3.5 inches W.C
1.1 inches W.C.
#38
28,000
20,000
71.90%
PAGE 14
LP GAS
NATURAL GAS
11.0 inches W.C.
5.0 inches W.C.
(recommended)
(7.0 W.C. recommended)
13.0 inches W.C.
10.5 inches W.C.
10.0 inches W.C.
NA
6.3 inches W.C
NA
#.0625
#38
28,000
28,000
21,000
20,000
74%
71.90%
56701-IPI
LP GAS
11.0 inches W.C.
(recommended)
13.0 inches W.C.
NA
NA
#.0625
28,000
21,000
74%