Vertical Min. / Max. Venting Illustrations; Restrictor Installation - kozy heat DASSEL DSL-36 Installation And Operation Manual

Table of Contents

Advertisement

VERTICAL TERMINATIONS
MIN. / MAX. VERTICAL VENTING (5" x 8")
Figure 22a
NOTE: Horizontal Vent Heat Shield is not used on vertical venting configurations.
NOTE: Depending on your particular venting needs, a Decreaser may be necessary to terminate venting system.
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.

RESTRICTOR INSTALLATION

RECOMMENDED:
Vertical terminations over 6ft. (1.82m): 1 restrictor
Maximum vertical terminations: 2 offset restrictors
Large Restrictor
Remove tab (s) to
create small restrictor
Figure 22c
NOTE: Page 49 has information on restrictor recommendations depending on burner flame appearance and instructions on installation
after venting is completed.
VENTING
TERMINATION CAP
MINIMUM: 4ft. (1.22m)
MAXIMUM: 40ft. (12.19m)
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
MIN. / MAX. VERTICAL VENTING
(8" x 6-5/8" DECREASER)
Figure 22b
Slide restrictor into exhaust pipe on top of fireplace with tabs
pointing towards you prior to attaching venting.
PAGE 22
TERMINATION CAP
MINIMUM: 4ft. (1.22m)
MAXIMUM: 40ft. (12.19m)
8" x 6-5/8" DECREASER
6" (152mm)