Minimum Venting For Corner Installation - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

HORIZONTAL TERMINATIONS
NOTE: Horizontal sections require 1/4" (6 mm) rise for every 12" (305 mm) of travel.
NOTE: Flange on top stand-off must be bent upwards to a 90˚ angle when top venting.
NOTE: Page 22 has information on restrictor installation in conjunction with venting installation. Page 51 has information on
Restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed.
IMPORTANT: If top venting, follow instructions on pages 16-17 to convert fireplace from rear vent ready to top vent ready
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
TYPICAL CORNER INSTALLATION
90° elbow + horizontal pipe + termination cap.
VENTING DIMENSIONS FOR MINIMUM CORNER INSTALLATIONS
Vent Opening Dimensions: Refer to vent pipe manufacturer's instructions
90° ELBOW
Figure 20a
VENTING
PIPE
TERMINATION CAP
PAGE 20
HORIZONTAL
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thief river falls 56701-ipiThief river falls 56701

Table of Contents