Finalizing The Installation; Burner Tube Adjustment / Troubleshooting - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

FINALIZING THE INSTALLATION

FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING SHOULD ONLY BE PERFORMED BY A QUALIFIED
PROFESSIONAL SERVICE TECHNICIAN.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
1/8" (3 mm) OPEN
VENTURI POSITION
Closed too far
Open too far
NOTE: If soot is present, check log positioning before adjusting burner venturi. Logs must not block burner ports.
IMPORTANT: SLIGHT ADJUSTMENTS TO BURNER VENTURI OPENING CREATE DRAMATIC RESULTS. ADJUST AT SLIGHT INCREMENTS
UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES AND ALLOW TIME TO COOL
BEFORE MAKING ANY FURTHER ADJUSTMENTS.
TO ADJUST VENTURI:
WARNING: To avoid property damage or personal injury, allow fireplace ample time to cool before making any adjustments.
1.
Remove upper louver and hood. Refer to page 32.
2.
Remove glass frame assembly. Refer to page 12.
3.
Remove log set.
4.
Remove burner tube.
5.
Loosen screw on burner venturi and adjust as necessary.
Tighten screw.
6.
Reinstall all components previously removed.
7.
Light fireplace and wait 15 minutes before determining if any further
adjustments are needed.
LP (PROPANE) GAS
5/8" (16 mm) OPEN
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames
VENTURI ADJUSTMENT
Open venturi setting slightly
Close venturi setting slightly
Figure 50a
PAGE 50
BURNER VENTURI