Prepare The Fireplace; Nailing Flange Assembly & Installation; Top Stand-Off Adjustment - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

NAILING FLANGE ASSEMBLY & INSTALLATION
When installed, nailing flanges provide the minimum 1/4" (6 mm) clearance from fireplace sides.
1.
Remove (4) nailing flanges from fireplace sides.
2.
With the 1/4" (6 mm) stand-offs on nailing flanges facing away from fireplace, align nailing flange with holes on outside corners of
fireplace. Secure with screws (provided with components packet) through slots in nailing flanges.
3.
Bend perforation on nailing flange until parallel with fireplace face. Do not bend toward fireplace face.
4.
Position framing stud against 1/4" (6 mm) stand-off located on backside of nailing flange and secure with nails or screws.
NOTE: Depending on facing material, nailing flanges can be adjusted forward or backwards up to 1/2" (13 mm).
CAUTION: Never permanently remove these assemblies from fireplace. They must be secured in place regardless of finish material used.
NAILING FLANGES
INSTALLED
AS SHIPPED
Figure 8a

TOP STAND-OFF ADJUSTMENT

The top stand-off is adjustable to accommodate finish material thickness (non-combustible material only).
TO ADJUST: Loosen screws at fireplace top, slide top stand-off to desired position, retighten screws.
TOP STAND-OFF ADJUSTMENT SLOTS
Figure 8b

PREPARE THE FIREPLACE

1/4" (6mm)
CLEARANCE
FRONT VIEW
NAILING FLANGE
1/4" (6mm)
CLEARANCE
FRAMING STUD
8
STAND-OFF
FRAMING STUD
NAILING FLANGE
TOP VIEW

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thief river falls 56701-ipiThief river falls 56701

Table of Contents