Ipdu-Sx; Secure Remote Power Reboot Switch; Installation And Operation Manual; Introduction - Network Technologies IPDU-Sx Installation And Operation Manual

Enviromux series secure remote power reboot switch
Table of Contents

Advertisement

NTI Secure Remote Power Reboot Switch

INTRODUCTION

The ENVIROMUX® IPDU-Sx Secure Remote Power Reboot Switch allows you to remotely reboot and control power (ON/OFF) or
to schedule periodic power cycles to servers or other powered devices from any location via secure web interface, RS232, SSH,
or Telnet.
Models Include:
Model
Decription
2-Outlet
IPDU-S2
IPDU-S4-P10
4-Outlet, for Euro/UK
4-Outlet, for US/Canada
IPDU-S4-P15
-P10 models include IEC 320-C13 outlets
-P15 models include NEMA 5-15R outlets
Features:
Supports Power ON or OFF in addition to Reboot.
Three operating modes for power control:
o
Manual — user can power cycle an outlet for a configured time sequence or power an outlet ON or OFF.
o
Periodic — set a date, time, and duration of the power cycle. Power cycles can also be scheduled as recurring
daily, weekly, or monthly.
o
Associated — power ON or OFF a device when a sensor exceeds a user-defined threshold, or power cycle if an
IP device is unresponsive.
Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password
authentication, user account restricted access rights.
Power Up Sequencing limits in-rush current.
Monitor (ping) up to 8 IP network devices.
o
Configure the timeout and number of retries to classify a device as unresponsive.
Power cycle associated power outlets if devices are not responding.
o
o
Alerts are sent if devices are not responding.
Outlets can be individually named (up to 80 characters).
Monitor environmental conditions.
Supports two sensors, including: temperature, humidity, and water detection.
o
o
When a sensor goes out of range of a configurable threshold, the system will notify you via email, syslog, LEDs,
web page, and network management (SNMP).
o
Powers up or down devices when sensors go out of range of user-defined thresholds.
Operates on a hardened Linux system.
Firmware upgradeable "in-field" through console port or Ethernet.
Up to 17 units can be cascaded into a system of up to136 outlets controlled either locally via RS485 or remotely via web
interface (models IPDU-S4 and IPDU-S8 only)
Line Monitoring (IPDU-S4 and IPDU-S8 only)
Monitor outlet voltage
o
o
Monitor outlet current
Monitor outlet frequency
o
o
Monitor circuit breaker status
Configurable events (IPDU can send alerts or control outlets as reaction to specific sensor readings) (models IPDU-S4
and IPDU-S8 only)
Model
Decription
IPDU-S8-P10
8-Outlet, for Euro/UK
IPDU-S8-P15
8-Outlet, for US/Canada
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enviromux ipdu-sx

Table of Contents