Set-up Procedure
Creation of
APPC-controller
48
The set-up involves the following steps:
1. Creation of APPC-controller.
2. Creation of RWS-controller.
3. Creation of Printer Devices.
4. VARY ON of the controllers and devices.
5. Set the Print Server Parameter AUTODIAL to YES.
Type CRTCTLAPPC to create a APPC controller description. Set your
choices in the panel as follows:
• Controller description: Select the name you want for the controller.
• Link Type: Select *LAN.
• APPN-capable: This must be set to *YES.
• Switched line list: Enter the name of the appropriate Line
Description.
• Maximum frame size: Select 1033.
• Remote network identifier: This parameter is the remote network
ID where the Print Server is located. This value must match the
setting of the Print Server Parameter NWORK_NAME. The
default is APPN.
• Remote control point: This parameter is the control point name of
the Print Server. This value is used to correlate the APPC controller
to a specific RWS controller. This value must mach the Print
Server Parameter CP_NAME. Refer to the AXIS 570/670 MIO
Set-up section for the default value.
• LAN remote adapter address: Enter the MAC address of the Print
Server.
• APPN CP session support: Select *NO.
• APPN node type: Select *LENNODE.