• number is the bar code definition number in the range 0 to 15.
This number is used to refer to the definition when printing the bar
code.
• type is the predefined bar code type. Valid values are:
Value
Description
CODE39
Code 39
UPC version A
UPCA
EAN8
EAN-8
EAN-13
EAN13
• width is the bar code module width in 1/1000 inch. Valid range is
1 to 1000. The default value is 12.
• height is the bar code element height in 1/24 inch. Valid range is 1
to 500. The default value is 12.
• text mode selects if human readable text is printed under the bar
code or not. "YES" or "ON" will turn on text, "NO" or "OFF" will
turn off text. The default mode is "ON".
• check mode selects if a check digit will be generated or not. "YES"
or "ON" will generate a check digit, "NO" or "OFF" will not gen-
erate a check digit. The default mode is "ON". The check digit will
always be generated for bar code types UPCA, EAN8 and EAN13,
regardless of the setting of check mode.
To set up the BAR parameter it is convenient to use the
command in your document. To print bar codes, bar code commands
may be included anywhere in your documents. They begin with
'percent-slash' (
) followed by the word BAR. Then follows the
%/
number of the bar code definition to be used, a comma, and the
sequence to be printed. The command is ended by a semi-colon (;).
Value
Description
CODE128
Code 128
2 of 5 Interleaved
INT2OF5
CODABAR Codabar matrix
%CONFIG
AXIS 570/
670 MIO
151