Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f010d-0400xxxx
The Drive n Status
806f010d-0401xxxx
has been disabled
806f010d-0402xxxx
due to a detected
806f010d-0403xxxx
fault.
806f010d-0404xxxx
(n = hard disk drive
806f010d-0405xxxx
number)
806f010d-0406xxxx
806f010d-0407xxxx
806f010d-0408xxxx
806f010d-0409xxxx
806f010d-040axxxx
806f010d-040bxxxx
806f010d-040cxxxx
806f010d-040dxxxx
806f010d-040exxxx
806f010d-040fxxxx
806f020d-0400xxxx
The Drive n Status
806f020d-0401xxxx
has a predictive
806f020d-0402xxxx
failure.
806f020d-0403xxxx
(n = hard disk drive
806f020d-0404xxxx
number)
806f020d-0405xxxx
806f020d-0406xxxx
806f020d-0407xxxx
806f020d-0408xxxx
806f020d-0409xxxx
806f020d-040axxxx
806f020d-040bxxxx
806f020d-040cxxxx
806f020d-040dxxxx
806f020d-040exxxx
806f020d-040fxxxx
806f050d-0400xxxx
Array %1 is in critical
806f050d-0401xxxx
condition.
806f050d-0402xxxx
(%1 =
806f050d-0403xxxx
CIM_ComputerSystem.
806f050d-0404xxxx
ElementName)
806f050d-0405xxxx
806f050d-0406xxxx
806f050d-0407xxxx
806f050d-0408xxxx
806f050d-0409xxxx
806f050d-040axxxx
806f050d-040bxxxx
806f050d-040cxxxx
806f050d-040dxxxx
806f050d-040exxxx
806f050d-040fxxxx
Error
A drive has been
disabled because
of a fault.
Warning
A predictive failure
has been detected
for drive n.
(n = hard disk drive
number)
Error
An array is in a
critical state.
(Sensor = Drive n
Status)
(n = hard disk drive
number)
1. Run the hard disk drive diagnostic
test on drive n.
2. Reseat the following components:
a. Hard disk drive (wait 1 minute
or more before reinstalling the
drive).
b. Cable from the system board to
the backplane
3. Replace the following components
one at a time, in the order shown,
restarting the server each time:
a. Hard disk drive
b. Cable from the system board to
the backplane
c. Hard disk drive backplane
(n = hard disk drive number)
1. Make sure that the RAID adapter
firmware and hard disk drive
firmware is at the latest level.
2. Make sure that the SAS cable is
connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is
indicated by a lit status LED.
Chapter 3. Diagnostics
79