Removing a hot-swap ac power supply

To remove a power supply, complete the following steps.
Power supply
filler panel
1. Read the safety information that begins on page vii and "Installation guidelines"
2. If only one power supply is installed, turn off the server and peripheral devices.
3. Disconnect the power cord from the power supply that you are removing.
4. Grasp the power-supply handle.
5. Press the orange release latch to the left and hold it in place.
6. Pull the power supply part of the way out of the bay, then release the latch and
7. If you are instructed to return the power supply, follow all packaging instructions,

Installing a hot-swap ac power supply

The following notes describe the type of ac power supply that the server supports
and other information that you must consider when you install a power supply:
v Make sure that the devices that you are installing are supported. For a list of
v Before you install an additional power supply or replace a power supply with one
v The server comes with one hot-swap 12-volt output power supply that connects
v Power supplies in the server must be with the same power rating or wattage to
v Power supply 1 is the default/primary power supply. If power supply 1 fails, you
v You can order an optional power supply for redundancy.
on page 191.
support the power supply as you pull it the rest of the way out of the bay.
and use any packaging materials for shipping that are supplied to you.
supported optional devices for the server, see http://www.ibm.com/systems/info/
x86servers/serverproven/compat/us/.
of a different wattage, you may use the IBM Power Configurator utility to
determine current system power consumption. For more information and to
download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
to power supply bay 1. The input voltage is 100-127 V ac or 200-240 V ac
auto-sensing.
ensure that the server will operate correctly. For example, you cannot mix
750-watt and 900-watt power supplies in the server.
must replace the power supply immediately.