IBM System x3650 M4 Type 7915 Problem Determination And Service Manual page 109

Hide thumbs Also See for System x3650 M4 Type 7915:
Table of Contents

Advertisement

Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f000f-220101xx
The System %1
encountered a POST
Error.
(%1 =
CIM_ComputerSystem.
ElementName)
806f000f-220102xx
The System %1
encountered a POST
Error.
(%1 =
CIM_ComputerSystem.
ElementName)
Error
There is no
memory detected.
(Sensor =
Firmware Error)
Error
There is insufficient
memory to
continue operation.
(Sensor =
Firmware Error)
1. Make sure the server meets the
minimum configuration to start
(see "Power-supply LEDs" on page
135).
2. Update the server firmware on the
primary page.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
3. (Trained technician only) Replace
the system board (see "Removing
the system board" on page 290 and
"Installing the system board" on
page 292).
1. Make sure the server meets the
minimum configuration to start
(see "Power-supply LEDs" on page
135).
2. Update the server firmware on the
primary page.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
3. (Trained technician only) Replace
the system board (see "Removing
the system board" on page 290 and
"Installing the system board" on
page 292).
Chapter 3. Diagnostics
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents