Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f0608-1301xx03
Power supply PS
Configuration error
with rating mismatch.
806f0312-2201xxxx
Entry to aux log has
asserted.
80080128-2101xxxx Low security jumper
presence has
asserted.
8008010f-2101xxxx
Physical presence
jumper presence has
asserted.
806f0028-2101xxxx
TPM command fail
has asserted.
Firmware and software messages
806f000f-220103xx
System encountered
firmware error -
unrecoverable boot
device failure.
806f000f-220104xx
System has
encountered a
motherboard failure.
806f000f-220107xx
System encountered
firmware error -
unrecoverable
keyboard failure.
Error
A power supply
configuration error
(rating mismatch)
has occurred.
Info
Entry to aux log
has been detected.
Info
The low security
jumper has been
detected.
Info
The physical
presence jumper
has been detected.
Error
The TPM sensor
access has been
degraded or
unavailable.
Error
A system firmware
error unrecoverable
boot device failure
has occurred.
Error
A fatal
motherboard failure
in the system has
been detected.
Error
A system firmware
error unrecoverable
keyboard failure
has occurred.
1. Make sure that the power supplies
installed are with the same rating or
wattage.
2. Reinstall the power supplies with
the same rating or wattage.
No action; information only.
No action; information only.
No action; information only.
1. Turn off the server and disconnect
the power cords. Reconnect the
power cords and restart the server.
2. If the problem remains, (trained
technician only) replace the system
board (see "Removing the system
board" on page 290 and "Installing
the system board" on page 292).
This is a UEFI detected event. The
UEFI diagnostic code for this event can
be found in the logged IMM message
text. Please refer to the UEFI
diagnostic code in the "UEFI diagnostic
code" section of the Info Center for the
appropriate user response.
This is a UEFI detected event. The
UEFI diagnostic code for this event can
be found in the logged IMM message
text. Please refer to the UEFI
diagnostic code in the "UEFI diagnostic
code" section of the Info Center for the
appropriate user response.
This is a UEFI detected event. The
UEFI diagnostic code for this event can
be found in the logged IMM message
text. Please refer to the UEFI
diagnostic code in the "UEFI diagnostic
code" section of the Info Center for the
appropriate user response.
Chapter 3. Diagnostics
89