IBM System x3650 M4 Type 7915 Problem Determination And Service Manual page 152

Hide thumbs Also See for System x3650 M4 Type 7915:
Table of Contents

Advertisement

Table 7. Light path diagnostics panel LEDs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
LED
Description
BOARD
An error has occurred on the
system board or the system
battery.
HDD
A hard disk drive has failed or is
missing.
134
IBM System x3650 M4 Type 7915: Problem Determination and Service Guide
Action
1. Check the LEDs on the system board to identify the
component that caused the error. The BOARD LED can
be lit due to any of the following reasons:
v Battery
v (Trained technician only) System board
2. Check the system-error log for information about the error.
3. Replace the failing component:
v Battery (see "Removing the battery" on page 273 and
"Installing the battery" on page 275).
v (Trained service technician only) System board (see
"Removing the system board" on page 290 and
"Installing the system board" on page 292).
1. If the CONFIG LED is not lit, complete the following steps
to correct the problem:
a. Check the LEDs on the hard disk drives for the drive
with a lit status LED and reseat the hard disk drive.
b. Reseat the hard disk drive backplane.
c. For more information, see "Hard disk drive problems"
on page 104.
d. If the error remains, replace the following components
one at a time, in the order listed, restarting the server
after each:
1) Replace the hard disk drive.
2) Replace the hard disk drive backplane.
e. If the problem remains, go to http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008&lndocid=SERV-CALL.
2. If the HDD LED and the CONFIG LED are lit, complete
the following steps to correct the problem:
a. Check the microprocessor installed is Intel E5-2690. If
it is, check the 2.5-inch hard disk drives installed is
lesser than eight.
b. Check the system-error logs for information about the
error. Replace any component that is identified in the
error log.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents