Parameter
Default
Decoding
Not Active
Check Digit
MOD 10 checked and transmitted
Bar Code Length
Minimum Length = 6
typedef enum tagMsiDecoding
{
ITC_MSI_NOTACTIVE = 0, // Default
ITC_MSI_ACTIVE = 1,
ITC_MSI_NO_CHANGE = 255
} ITC_MSI_DECODING;
typedef enum tagMsiCheckDigit
{
ITC_MSI_CHECK_MOD10_XMIT, // Default
ITC_MSI_CHECK_MOD10_NOTXMIT,
ITC_MSI_CHECK_DOUBLEMOD10_XMIT,
ITC_MSI_CHECK_DOUBLEMOD10_NOTXMIT,
ITC_MSI_CHECK_NO_CHANGE = 255
} ITC_MSI_CHECK_DIGIT;
#define ITC_BC_LENGTH_NO_CHANGE 255. This definition can be used when the bar
code length does not require any change.
200
Note: The following default settings and enumerations apply to both the
IS9CConfig::GetMSI and IS9CConfig::SetMSI functions.
MSI Default Settings
MSI Enumerations
Valid Range
ITC_MSI_DECODING
ITC_MSI_CHECK_DIGIT
0x00–0xFE ITC_BC_LENGTH_NO_CHANGE