Ioctl_Hal_Itc_Read_Parm - Intermec 700 Series User Manual

Color mobile computer
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

IOCTL_HAL_ITC_READ_PARM

700 Series Color Mobile Computer User's Manual
Usage
#include "oemioctl.h"
Syntax
BOOL KernelIoControl( IOCTL_HAL_ITC_READ_PARM,LPVOID
lpInBuf,DWORD nInBufSize,LPVOID lpOutBuf,DWORD
nOutBufSize,LPDWORD lpBytesReturned );
Parameters
S lpInBuf
Points to this structure. See "ID Field Values" below.
struct PARMS {
BYTE id;
BYTE ClassId;
};
S nInBufSize
Must be set to the size of the PARMS structure.
S lpOutBuf
Must point to a buffer large enough to hold the return data of the func-
tion. If this field is set to NULL and nOutBufSize is set to zero when
the function is called the function will return the number bytes required
by the buffer.
S nOutBufSize
The size of lpOutBuf in bytes.
S lpBytesReturned
The number of bytes returned by the function for the data requested.
Return Values
Returns TRUE if function succeeds. Returns FALSE if the function fails.
GetLastError() may be used to get the error value. Either
ERROR_INVALID_PARAMETER or
ERROR_INSUFFICIENT_BUFFER may be returned when this function
is used to get the error.
ID Field Values
The id field of the PARMS structure may be one of the following values:
S ITC_NVPARM_ETHERNET_ID
This IOCTL returns the Ethernet 802.11 MAC Address. Six bytes are
returned in the buffer pointed to by the lpOutBuffer parameter.
S ITC_NVPARM_SERIAL_NUM
This IOCTL returns the serial number of the device in BCD format.
Six bytes are returned in the buffer pointed to by the lpOutBuffer pa-
rameter.
S ITC_NVPARM_MANF_DATE
This IOCTL returns the device date of manufacture in the
BCD YYYY/MM/DD format. Four bytes are returned in the buffer
pointed to by the lpOutBuffer parameter.
Chapter 7
Programming
291

Advertisement