Is9Cconfig::setcode39 - Intermec 700 Series User Manual

Color mobile computer
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Chapter
6
Scanner Support
184

IS9CConfig::SetCode39

This function updates the Code 39 settings with new values.
Syntax
HRESULT IS9CConfig::SetCode39( ITC_CODE39_DECODING
eDecode,ITC_CODE39_FORMAT eFormat, ITC_CODE39_START_STOP
eSS,ITC_CODE39_SS_CHARS eSSChars, ITC_CODE39_CHECK_DIGIT
eCheck, DWORD dwLength );
Parameters
eDecode
[in] Identifies the decoding for Code 39.
eFormat
[in] Identifies the Code 39 Format.
eSS
[in] Identifies the Start/Stop option.
eSSChars
[in] Identifies the Start/Stop character.
eCheck
[in] Identifies the Check digit.
dwLength
[in] Identifies the bar code length.
Return Values
HRESULT that indicates success or failure.
Remarks
None.
See Also
None.