NEC Express 5800 User Manual page 643

Express5800 series
Hide thumbs Also See for Express 5800:
Table of Contents

Advertisement

(2) Enter <select> command on the command line of the System Diagnostics screen to select
the test required device.
- The followings are three ways of specifying the test device.
1. Specifying "Test device number": Specifies the test device number of "Num" row
individually.
When specifying a device that "+" or "-" is added on the top of the device name, all the
devices under the tree is selected.
2. Specifying "Test device type": Specifies the test device type of "Type" row. This
specifies the same type of devices.
3. Specifying "all": Specifies all the test devices. # Specify <all> in general.
If there is no media in the DVD, the test for them will fail.
So, ignore the test result for them or do not execute the test for them.
The below is an example of specifying <Test device number>.
Check the executed result of <select> command with the <list> command.
TeDoLi> select 19
TeDoLi> list
+----+-+---------------------------------+------------+----+-------------+
| Num|*| Device List
+----+-+---------------------------------+------------+----+-------------+
|
1| | MEMORY
|
2|!|-MGM2
|
3|!| -MGM2/MGB/GbE
|
4| |
Port1(eth1)
|
5| |
Port2(eth2)
|
6|!|-PMM5
|
7| | PMM5/PMB/PROC
|
8|!|-PMM6
|
9| | PMM6/PMB/PROC
| 10|!|-BM
| 11|!| -BM/MB/PCI1
| 12|!|
Port1
| 13|!| -BM/MB/PCI8
| 14| |
Port1(eth0)
| 15|!| -BM/MB/PCI9
| 16|!| -Port1
| 17| |
SCSI-ID0 LUN0(iStorage 1000) |HDD
| 18|!|
Port2
| 19|*| DV-28S-V
+----+-+---------------------------------+------------+----+-------------+
| Type
|Prev| Status
|MEMORY
|
|
|MODULE
|
|
|NIC
|
|
|ETH-PORT
|
|
|ETH-PORT
|
|
|MODULE
|
|
|CPU
|
|
|MODULE
|
|
|CPU
|
|
|MODULE
|
|
|SCSI(NoDev) |
|
|SCSI-PORT
|
|
|NIC
|
|
|ETH-PORT
|
|
|FC
|
|
|FC-PORT
|
|
|
|
|FC-PORT
|
|
|DVD
|
|
643
Operation and Maintenance
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents