< Description>
(1) Name of the system and firmware version
System name
Firmware version : Management firmware version.
(2) System Health: Status of system
Name
Power
Health
(3) Server Health: Status of server
ID
Name
PowerServer
H ealth
Status
: Name of the system is displayed. N/A is displayed when there is no
name.
: Name of the system is displayed. N/A is displayed when there is no
name.
: DC power status is displayed.
Display Value
Off
On
: Failure status is displayed. This indicates the worst status among all the
Servers, including the spare server.
Display Value
Normal
Non-Critical
Critical
: [0] indicates Server 1 (including MGM1). [1] indicates Server 2 (including
MGM2).
: Name of the server is displayed. N/A is displayed when there is no
name.
: DC power status of Server
Display Value
Off
On
: Failure status is displayed. This indicates the status of the relevant
server.
Display Value
Normal
Non-Critical
Critical
: Operating status of the server
Display Value
Stopped
BIST Running
Initializing
Description
DC power of all Servers is OFF
DC power of at least one Server is ON
Description
No failure occurred, or only Correctable Error
occurred.
Recoverable Error occurred. Maintenance of the
system is required.
Fatal error occurred. Maintenance of the system
is required.
Description
DC power of the relevant Server is OFF.
DC power of the relevant Server is ON.
Description
No failure occurred, or only Correctable Error
occurred.
Recoverable Error occurred. Maintenance of the
Server is required.
Fatal Error occurred. Maintenance of the Server
is required.
Description
Server stopped (DC OFF)
BIST Running status
Booting up (loading) status
618
Operation and Maintenance