Code 128 / Ean128; Pdf417 - Datalogic MAGELLAN 8200 Product Reference Manual

Table of Contents

Advertisement

Product Reference Guide

Code 128 / EAN128

Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
Label length excluding prefix character must meet requirements
imposed by the main scanner's fixed or variable label length con-
trol for this symbology type.
If EAN-128 Symbology is Enabled and prefix is ']C1', label will
be identified as an EAN128 otherwise it is identified as a Code
128.
A prefix of ']C0' designates that no function code is present in the
1st or 2nd character position.
A prefix of ']C2' designates that a function code 1 is present in
the 2nd character.
Example : ']C0Code_128.Test'.

PDF417

Prefix must be an ASCII characters ']L0'.
Label length excluding prefix character cannot exceed 300 charac-
ters. In addition to this, label length excluding prefix character must
meet requirements imposed by the main scanner's fixed or variable
label length control for this symbology type.
Example : ']L0pdf_test_label'.