Codabar; Code 128 - Datalogic MAGELLAN 8200 Product Reference Manual

Table of Contents

Advertisement

F-8

Codabar

Check character must be included in label data.
Label length including check character and excluding prefix char-
acter must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.
Prefix must be an ASCII character '%'.
Start stop character sets must meet the matching requirement set
forth by the scanner configuration item Codabar Start Stop Char-
acter Match.
Start stop character sets must be of the form ABCD/ABCD and
must be included in the label.
Example: '%s$99.95s' (the lower case 's' at each end of the exam-
ple is a placeholder for the start stop character set).

Code 128

Prefix must be an ASCII character '#'.
Label length excluding prefix character must meet requirements
imposed by the main scanner's fixed or variable label length con-
trol for this symbology type.
Function characters may be transmitted as a hexadecimal value
8x. Where x correlates to function characters 1 thru 4 as follows:
x80 = function code 1
x81 = function code 2
x82 = function code 3
x83 = function code 4
For Code 128 programming labels the format is of the general
form '#/82nnnnn/r ' - /82 is hexadecimal 82 and /r is carriage
return.
Example: '#Code_128.Test'.
®
Magellan
8100/8100
Ω
/
and 8200
8200
Ω
Scanner

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents