Code 39 Minimum Label Length - Datalogic MAGELLAN 8200 Product Reference Manual

Table of Contents

Advertisement

Code 39 Minimum Label Length

NOTE
6-190
This feature specifies the minimum allowable length of a Code 39 label.
Length in this case includes check, data and ASCII characters, but does
not include start, or stop characters. This feature applies when Code 39
Length Control is set to variable-length decoding.
Minumum label length should be less than or equal to maximum label
length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET CODE 39 MINIMUM LABEL
LENGTH below. You'll need to cover any unused bar codes on
this and the facing page to ensure that the scanner reads only the
bar code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired minimum label length. The selectable range
for this option is 00 to 50. Pad all single digit numbers with a
leading zero to yield a two-digit entry (00-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODE 39 MINIMUM LABEL LENGTH
®
Magellan
Ω
8100/8100
and 8200
/
Ω
8200
Scanner

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents