Calibration Verification (U.S. Pounds)

5-8
Once you have completed the calibration sequence, you may be required
to perform these step-by-step verification procedures. These procedures
follow the National Institute of Standards and Technology Handbook-44
guidelines for grocery scale installations. You may be required by state or
local law to have these procedures performed by a certified technician or
verified by a proper official.
These calibration verification procedures cover five different tests:
Increasing-Load Test
Shift Test
Blanking Test
Decreasing-Load Test
Return to Zero Test
®
Magellan
8100/8100
Ω
/
and 8200
8200
Ω
Scanner