I 2 of 5 Minimum Label Length

NOTE
Product Reference Guide
This feature specifies the minimum allowable length of an I 2 of 5 label.
Length in this case includes check and data characters, but does not
include start or stop characters. This feature applies when I 2 of 5
Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label
length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET I 2 OF 5 MINIMUM LABEL LENGTH
below. You'll need to cover any unused bar codes on this and the
facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired minimum label length. The selectable range
for this option is 02 to 50, even numbers only. Pad all single digit
numbers with a leading zero to yield a two-digit entry (02-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET I 2 OF 5 MINIMUM LABEL LENGTH
6-219