Figure 2-3. Debris Chutes & Ventilation Slots

Service Access

2-8
If motors, conveyor belts, or other heat producing equipment are located
near the scanner, forced air ventilation may be required. In most installa-
tions, a 30 cfm (.84 cmm) axial fan should provide sufficient air move-
ment. If a ventilation fan is installed, one with a removable filter that may
be washed or replaced is recommended.
Debris Chutes/Ventilation Slots
The scanner and scanning-scale have been engineered to allow perfor-
mance of all routine service and maintenance (such as "zeroing" and cali-
bration) without removing the scanner from the checkstand. Additionally
all cable connections made at the scanner can be connected and removed
while the unit is sitting on the countertop. The installer should provide
service access to all remaining cable connectors as well as the AC/DC
Power Supply (if installed).
®
Magellan
8100/8100
Ω
/
and 8200
8200
Ω
Scanner