Good Read Beep Length

6-26
Specifies the duration of a good read beep.
To set the good read beep length:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET GOOD READ BEEP LENGTH. You'll
need to cover any unused bar codes on this and the facing page to
ensure that the scanner reads only the bar code you intend to
scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired good read beep length setting. The select-
able range is 1-255, which is the timeout in 10-millisecond incre-
ments. Pad all single and double digit numbers with leading
zeroes to yield a three-digit entry (001-255).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming Mode when the
appropriate amount of digits have been scanned