DataBar Expanded Minimum Label Length

NOTE
Product Reference Guide
This feature specifies the minimum allowable length of an DataBar
Expanded label.
Length in this case includes check and data characters. This applies
when DataBar Expanded Length Control is set to variable-length
decoding.
Minimum Label Length should be less than or equal to Maximum Label
Length.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET DATABAR EXPANDED MINIMUM
LABEL LENGTH below. You'll need to cover any unused bar-
codes on this and the facing page to ensure that the scanner reads
only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
represent the desired minimum label length. The selectable range
for this option is 00 to 74. Pad all single digit numbers with a
leading zero to yield a two-digit entry (00-74).
4. Complete the programming sequence by scanning the SWITCH
barcode.
SET DATABAR EXPANDED MINIMUM LABEL LENGTH
that
Appendix C