Activating an RRPP Domain
To activate an RRPP domain on the current device, enable the RRPP protocol and RRPP rings for the
RRPP domain on the current device.
Perform this operation on all nodes in the RRPP domain.
Follow these steps to activate an RRPP domain:
To do...
Enter system view
Enable RRPP
Enter RRPP domain view
Enable the specified RRPP ring
On an edge node or assistant-edge node, enable/disable the primary ring and subrings separately as
follows:
Enable the primary ring of an RRPP domain before enabling subrings of the RRPP domain.
Disable the primary ring of an RRPP domain after disabling all subrings of the RRPP domain.
Configuring RRPP Timers
Perform this configuration on the master node of an RRPP domain.
Follow these steps to configure RRPP timers:
To do...
Enter system view
Enter RRPP domain view
Configure the Hello timer and
Fail timer for the RRPP domain
Use the command...
system-view
rrpp enable
rrpp domain domain-id
ring ring-id enable
Use the command...
system-view
rrpp domain domain-id
timer hello-timer hello-value
fail-timer fail-value
1-15
Remarks
—
Required
Disabled by default
—
Required
Disabled by default
Remarks
—
—
Required
By default, the Hello timer value
is 1 second and the Fail timer
value is 3 seconds.