Port Fencing troubleshooting

The following section states a possible issue and the recommended solution for Port Fencing
errors.
TABLE 40
Problem
In a pure M-EOS fabric, fabric level policy
information (for example, Port Fencing Link
threshold) is stored in database based on the
principle switch WWN. Therefore, if you add a
switch to the fabric and the new switch becomes
the Principle switch, the Management
application cannot obtain the policy information
and the threshold is not applied.
If you segment a switch from a fabric then
rediscover the switch without accepting
changes, the Port Fencing dialog box displays
the switch twice and the port count is doubled.

Server Management Console troubleshooting

The following section states a possible issue and the recommended solution for server
management console.
632
Resolution
Re-assign the threshold to the fabric. For step-by-step instructions, refer to
thresholds"
on page 341.
Right-click on the fabric that the segmented switch (with red minus icon) is part of and
select Accept Changes.
"Assigning
DCFM Professional Plus User Manual