Brocade Communications Systems Brocade BladeSystem 4/24 User Manual page 531

Supporting dcfm 10.4.x
Hide thumbs Also See for Brocade BladeSystem 4/24:
Table of Contents

Advertisement

FIGURE 173
DCFM Professional Plus User Manual
53-1001774-01
Configuration Status dialog box
The Management application sends API commands to verify the switch configuration. The CLI
commands are detailed in the Fabric OS Encryption Administrator's Guide, "Key vault
configuration."
Initialize the switch
If the switch is not already in the initiated state, the Management application performs the
command.
cryptocfg --initnode
Create encryption group on the switch
The Management application creates a new group using the
command, and sets the key vault type using the
Register key vault(s)
The Management application registers the key vault using the
command.
Enable the encryption engines
The Management application initializes an encryption switch using the
and
[<slotnumber>]
cryptocfg --regEE [<slotnumber>]
cryptocfg --create -encgroup
cryptocfg --set -keyvault command
cryptocfg --reg keyvault
cryptocfg --initEE
commands.
18
.
497

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcfm professional plus

Table of Contents