ICP-CC488 | Installation Guide | 17.0
The Sensor Watch Time counter is active only when
the control panel is disarmed. If the system is
disarmed for 8 hours a day and the Sensor Watch
Time is programmed for 1 day, a zone programmed
for Sensor Watch registers a Sensor Watch Fault if it
is not activated while disarmed within 3 days.
This feature is useful, for example, when someone
places objects in the view of a motion detector, which
prevents the detector from picking up movement.
To disable Sensor Watch Reports, program Locations
389 and 390 as 0 (refer to Section 15.5 Zone Status –
Sensor Watch Reports on page 66).
17.8

Codepad Lockout Time

478
Location
0
No lockout
1 to 15
Lockout time (increments of 10 sec)
All codepads are locked out for the programmed
time if an invalid code is entered more times than
allowed by the code retry attempts programmed in
Location 424 (refer to Section 15.26 System Status –
Access Denied on page 69). If the Codepad Lockout
Time is programmed as 0, codepad lockout does not
occur.
17.9

Siren Run Time

479
Location
Default
5
0
No siren time
1 to 15
Siren time in min
The Siren Run Time determines how long the horn
speaker operates during an alarm. You can program
the Siren Run Time from 0 to 15 min in 1-min
intervals.

17.10 Siren Sound Rate

Location
480
7
Default
0
Slowest frequency
15
Fastest frequency
The Siren Sound Rate varies the frequency of the
siren tone slowest (0) and to fastest (15). The Siren
Sound Rate does not change the frequency of the fire
alarm tone.

17.11 Auto Arming Pre-Alert Timer

Location
481
Default
1
0
No alert time
1 to 15
Alert time (increments of 5 min)
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Event Timers
This location sets the time period during which the
control panel warns you it is automatically armed in
AWAY Mode. The codepad beeps once every
second until the Pre-Alert Timer expires: the system
then automatically arms itself in AWAY Mode. If
you want the system to automatically arm in STAY
Mode 1, enable Option 4 in Location 496 (refer to
Section 18.5 Consumer Options 1 on page 82).
After the control panel is automatically armed in
AWAY Mode or STAY Mode 1, Exit Time starts. If
a valid User Code is entered during the Pre-Alert
Time, the Auto Arming Time programmed in
Locations 482 to 485 (refer to Section 17.12 Auto
Arming Time on page 79) is extended by 1 hour.
If you want a programmable output to operate
during the Auto Arming Pre-Alert Time, use Output
Event Type 0,5 Auto Arm Pre-Arming Alert Time
(refer to page 71).

17.12 Auto Arming Time

Location
482 to 485
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
These locations specify the time of day the system
automatically arms itself in AWAY Mode. Set this
time in 24-hour format (for example, program 10:30
PM as 2230). If you want the system to arm in STAY
Mode 1, select Option 4 in Location 496 (refer to
Section 18.5 Consumer Options 1on page 82).
If forced arming is disabled for any zone, the
automatic arming feature operates regardless of
whether any zones are unsealed. Refer to Section
14.3.7 Zone Options 2 on page 63 for more
information on programming zones for forced
arming.
User Code 16 is reported when this feature is used.
For partitioned ICP-CC488 Control Panels, both
areas are automatically armed in AWAY Mode at the
same time each day.

17.13 Auto Disarming Time

486 to 489
Location
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
These locations specify the time of day the system
automatically disarms itself. Set this time in 24-hour
format (for example, program 10:30 PM as 2230).
User Code 16 is reported when this feature is used.
EN | 79
Location
Default
482
0
483
0
484
0
485
0
Location
Default
486
0
487
0
488
0
489
0