Bosch CC488 Quick Reference Manual

Bosch CC488 Quick Reference Manual

Solution ultima 880
Hide thumbs Also See for CC488:
Table of Contents

Advertisement

CC488
Quick Reference Guide
EN
Solution Ultima 880

Advertisement

Table of Contents
loading

Summary of Contents for Bosch CC488

  • Page 1 CC488 Quick Reference Guide Solution Ultima 880...
  • Page 2: Copyright Notice

    Bosch. material. Except as specified above or where authorised by the Bosch Security Systems Pty Ltd reserves the right to Copyright Act 1968 (Cth), no part of this publication make changes to features and specifications of its may be reproduced, transmitted, modified or stored, products at any time without prior notification.
  • Page 3: Table Of Contents

    CC488 | Quick Reference Guide | Contents EN | 3 2.1.8 Handshake Tone For Receiver 2 ....11 Contents 2.1.9 Transmission Format For Receiver 2 ...11 2.1.10 Subscriber ID Number For Receiver 2 ..11 Overview ............6 2.1.11 Dialling Format ..........11 Introduction............
  • Page 4 CC488 | Quick Reference Guide | Contents EN | 4 2.10.2 Open/Close Reporting Options....15 2.14.14 Speaker Beep Volume........19 2.10.3 Codepad Duress Report.........15 2.15 Options Programming........19 2.10.4 Codepad Panic Report........15 2.15.1 System Options 1 ..........19 2.10.5 Codepad Fire Report........15 2.15.2 System Options 2 ..........19 2.10.6 Codepad Medical Report ......15...
  • Page 5 CC488 | Quick Reference Guide | Contents EN | 5 Figures Tables Figure 1: RF Receiver (RF 3212/E) Wiring Table 1: Quick Guide to Programming....6 Diagram ............22 Table 2: Codepad Indicators ........7 Figure 2: RF3332/E – 2 Button RF Keyfob ..23 Table 3: Programming Option Bits......7...
  • Page 6: Overview

    CC488 | Quick Reference Guide | 1.0 Overview EN | 6 To move to another programming location, enter the 1.0 Overview location number followed by the [#] key. The data in the new location is displayed using the codepad Introduction indicators.
  • Page 7: Codepad Indicators

    CC488 | Quick Reference Guide | 1.0 Overview EN | 7 Table 2: Codepad Indicators Data Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 MAINS Value Indicator Indicator Indicator Indicator Indicator Indicator...
  • Page 8: Arming/Disarming The System

    CC488 | Quick Reference Guide | 1.0 Overview EN | 8 Arming/Disarming the System Table 5: Arming/Disarming the System AWAY Mode STAY Mode 1 STAY Mode 2 Arming Press and hold the [#] key until two Press and hold the [*] key until two...
  • Page 9: Satellite Siren Service Mode

    CC488 | Quick Reference Guide | 1.0 Overview EN | 9 1.12 Satellite Siren Service Mode 1.15 Change Domestic Telephone Numbers Enter the four character Installer Code, followed by [5] and the [#] key (for example, [1 2 3 4 5 #]).
  • Page 10: Modem Call (Alarm Link)

    CC488 | Quick Reference Guide | 1.0 Overview EN | 10 1.20 Fault Analysis 1.23 Codepad ID/Buzzer Tone 1. Press and hold the [5] key until two beeps are 1. Press and hold the [8] key until the desired heard.
  • Page 11: Programming Parameters

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 11 2.1.8 Handshake Tone For Receiver 2 2.0 Programming Location HI-LO handshake (contact ID) Parameters 1400 Hz (Ademco TX @ 1900 Hz) 2300 Hz (Sescoa TX @ 1800 Hz) No handshake Shaded rows indicate default values.
  • Page 12: Telephone Line Fail Options

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 12 2.1.17 Telephone Line Fail Options User Code Programming Location 2.3.1 User Codes Default Location 185 to 264 Display FAULT Indicator when telephone line fails Location Default Sound alarm when system is armed...
  • Page 13: Day Alarm Zones

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 13 Day Alarm Zones 2.6.1 Zone Defaults (continued) Location Location 267 to 322 Default Zone #04 (Default = Handover) Zone 1 Zone Type Zone 2 Zone Pulse Count Zone 3...
  • Page 14: Zone Types

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 14 2.6.2 Zone Types 2.6.8 Keyswitch Zone Options Zone Type Description The keyswitch zone options replace Zone Options 1 only for the zones that were programmed to Instant operate as a keyswitch zone.
  • Page 15: Zone Status – Sensor Watch Report

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 15 2.8.5 Zone Status – Sensor Watch Report 2.10.2 Open/Close Reporting Options Location 333 to 334 Location Location Default No Open/Close Reports allowed Sensor Watch Report Report to Receiver 1...
  • Page 16: System Status – Ac Fail Restore Report

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 16 2.11.4 System Status – AC Fail Restore 2.13 Output Programming Report 2.13.1 Outputs Location 362 to 363 Location 380 to 409 Location Default Location Default Tens digit Output 1 (Default = Horn Speaker)
  • Page 17: Event Codes

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 17 2.13.2 Event Codes 2.13.2 Event Codes (continued) Event Description Event Description Code Code EDMSAT – satellite siren (output 1 only) Communications fail System armed Dialler disabled System disarmed...
  • Page 18: Polarity (Modes)

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 18 2.14.4 Entry Guard Time For STAY Mode 2.13.3 Polarity (Modes) Location 416 to 417 Option Description Location Default Disabled Increments of 1 sec. (0 to 15 sec.) Normally open, going low Increments of 16 sec.
  • Page 19: Speaker Beep Volume

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 19 2.15.8 Radio Input Options 2.14.14 Speaker Beep Volume Location Location Default Default RF Receiver (RF-3212/E) connected No Beeps Latching keyswitch input Loudest Beeps Momentary keyswitch input 2.15 Options Programming Reserved 2.15.1...
  • Page 20: User Code Area Assignment

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 20 2.20.3 RF Device Mapping for Devices 9 to 2.17 User Code Area Assignment Location 462 to 477 Location 536 to 543 Location Default Location Default User Code 1...
  • Page 21: System Date

    CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 21 2.21.3 System Date Location 905 to 910 Location Default Day of the month (tens digit) Day of the month (units digit) Month of the year (tens digit) Month of the year (units digit)
  • Page 22: Solution Ultima Rf Receiver Interface

    CC488 | Quick Reference Guide | 3.0 Solution Ultima RF Receiver Interface EN | 22 3.0 Solution Ultima RF Receiver Interface Figure 1: RF Receiver (RF 3212/E) Wiring Diagram 1 = Solution Ultima Control Panel 2 = RF Receiver (RF 3212/E) Wiring and Power Up: 1.
  • Page 23: Rf Keyfob Operations

    CC488 | Quick Reference Guide | 4.0 RF Keyfob Operations EN | 23 4.0 RF Keyfob Operations 5.0 Connections for Split EOL Resistors Figure 2: RF3332/E – 2 Button RF Keyfob 8 Burglary Zones Figure 4: Split EOL Wiring Diagram...
  • Page 24: Split Eol Wiring Diagrams Using N/O Contacts

    CC488 | Quick Reference Guide | 6.0 Wiring Diagrams EN | 24 8 Zone Operation Using N/O Contacts Figure 6: Split EOL Wiring Diagrams Using N/O Contacts 1 = +12 V 6 = 6k8 2 = Zone Input 7 = 1k5...
  • Page 25: Solution Ultima Series

    CC488 | Quick Reference Guide | 6.0 Wiring Diagrams EN | 25 Solution Ultima Series Figure 8: Solution Ultima Series Wiring Diagram 1 = 605 Plug 7 = Link between +12 V and Comm 2 = 1 (Green) - Internal phone line...
  • Page 26: Figure 9: Solution Ultima Series Component Overlay

    CC488 | Quick Reference Guide | 7.0 Component Overlay EN | 26 Component Overlay Figure 9: Solution Ultima Series Component Overlay 1 = OUT – Internal phone line 7 = Relay contact select OUT – Internal phone line 8 = Programming key or hand help programmer plugs IN –...
  • Page 27: Figure 10: Connections For Cp-5 Master Partitioned

    CC488 | Quick Reference Guide | 8.0 Codepad Connections Partitioning EN | 27 8.0 Codepad Connections Figure 11: Connections for Two CP-5 Eight Zone Partitioning Area Addressable (CP500A) Codepads Figure 10: Connections for CP-5 Master Partitioned (CP500P) Codepad and CP-5 Area Addressable (CP500A)
  • Page 28 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 © 2004 Bosch Security Systems 4998152446B 05-SUB-MA88Q-3323 Issue 1.73...

This manual is also suitable for:

Solution ultima 880

Table of Contents