Send Test Report; Remote Arming By Telephone; Programming; Programming With The Remote Codepad - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 6.0
To determine the area to which the codepad
belongs:
1. Press and hold [8] until two beeps sound.
A zone indicator lights to show the area to which
the codepad belongs.
Zone 1 = Area 1 codepad
Zone 2 = Area 2 codepad
Zone 7 = Master Partitioned Codepad
If no zone indicator lights, the codepad is set up
incorrectly or an incorrect codepad is used.
2. Press [AWAY] to exit from this mode.
5.4.12

Send Test Report

Holding down [9] until two beeps sound transmits a
Test Report (Contact ID Event Code 602) to test the
dialing and reporting capabilities of the system
without activating the sirens.
6.0 Remote Arming by
Telephone
This feature allows you to arm your system from any
remote location by telephone. For obvious security
reasons, you cannot disarm the system using this
method. A touch-tone telephone is required to use
this feature.
To remotely arm your system by telephone:
1. Call the telephone number to which your control
panel is connected.
When the control panel answers the incoming
call, a short jingle sounds.
If you hear several strange sounding tones
when the control panel answers the
incoming call, the system is programmed
for remote programming functions. Wait
for a pause in the tones and follow Step 2
to arm the system remotely.
2. Hold the phone controller to the telephone's
mouthpiece and press and hold the button on the
side of the unit for 3 sec.
You can alternatively press and hold [*] on the
touch-tone telephone for 3 sec to arm the system.
Two beeps sound to indicate that the system is
armed in AWAY Mode.
3. Hang up the telephone.
The system remains armed.
If the control panel does not answer the call, the
system might be armed already, remote functions are
not enabled, or the ring count is set to 0. To enable
remote arming by telephone, select Option 2 in
Location 177 (refer to Section 12.1 Dialer Options 1 on
page 52). To set the number of rings before the
control panel answers, refer to Section 11.10 Ring
Count on page 51.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02

Remote Arming by Telephone

When both Remote Arming and
Upload/Download are selected, the
control panel answers the call expecting
the remote computer. When this occurs,
modem negotiating tones sound rather
than the remote arming jingle.
Using this method with a partitioned
ICP-CC488 Control Panel arms both
areas in AWAY Mode. Arming individual
areas is not available with this method.
7.0

Programming

The control panel programming options are stored in
a non-volatile EPROM. This memory holds all
relevant configuration and user-specific data even
after a total power loss.
Because the data retention time is up to ten years
without power, no reprogramming is required after
powering down the control panel.
You can change data as many times as required
without additional specialized equipment. The
memory is organized in locations, each of which
holds the data for a specific function.
The maximum value you can program into
any location is 15.
In general, the entire programming sequence consists
of selecting the required location, and then entering
or changing the current data. Repeat this procedure
until you program all required data. The factory
default settings are selected for reporting to the
monitoring station in Contact ID format.
The Installer Code provides access only to the
Installer's Programming Mode and does not allow
you to arm and disarm the system. You cannot enter
Installer's Programming Mode when the system is
armed, or at any time during siren run time.
You can program the ICP-CC488 Control Panel
using any of these devices:
Remote codepad
CC816 Alarm Link Upload/Download Software
7.1
Programming with the Remote
Codepad
To program the control panel using the remote
codepad, the system must be disarmed with no alarm
memory present.
To access Installer's Programming Mode:
Enter the four-digit Installer Code (the factory default
is 1234) and press [AWAY].
Two beeps sound and both the AWAY and the
STAY indicators flash simultaneously to indicate that
you entered Installer's Programming Mode.
EN | 34