Codepad Fire Report; Codepad Medical Report; Codepad Reporting Options; System Status - Aux Power Supply Fail Report - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 15.0
Restore Reports are not sent for this
event.
If Codepad Panic Reports are not
required, program Locations 405 and 406
as 0.

15.17 Codepad Fire Report

Location
407 to 408
Tens digit
Units digit
A Fire Alarm Report (Contact ID Event Code 110) is
sent to the base station receiver when a user presses
[4] and [6] at the same time. A Fire Alarm is audible,
but you can program the alarm as silent by selecting
Option 2 in Location 493 (refer to Section 18.2 System
Options 2 on page 81). A distinct fire sound is emitted
through the horn speaker to indicate this type of
alarm. The fire sound is different than the burglary
sound.
Restore Reports are not sent for this
event.
If Codepad Fire Reports are not required,
program Locations 407 and 408 as 0.

15.18 Codepad Medical Report

Location
409 to 410
Tens digit
Units digit
A Medical Report (Contact ID Event Code 100) is
sent to the base station receiver when a user presses
[7] and [9] at the same time. A Medical Alarm is
audible, but you can program the alarm as silent by
selecting Option 4 in Location 493 (refer to Section
18.2 System Options 2 on page 81).
Restore Reports are not sent for this
event.
If Codepad Medical Reports are not
required, program Locations 409 and 410
as 0.

15.19 Codepad Reporting Options

Location
411
0
No Codepad Alarm Reports allowed
1
Report to Receiver 1
2
Report to Receiver 2
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1 fails
Location 411 is set by default to report only to
Receiver 1. You can select whether Codepad Alarm
Reports are sent to Receiver 1, Receiver 2, or both,
Receiver 2 only when Receiver 1 fails, or no
reporting.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Reporting Information
15.20 System Status – AUX Power
Location
Tens digit
Units digit
A System Trouble Report (Contact ID Event Code
300) is sent when either the codepad AUX power
Location
Default
supply is blown or the AUX power supply
407
7
malfunctions. The system reports the event
408
14
approximately 10 sec after the failure.
15.21 System Status – AUX Power
Location
Tens digit
Units digit
A System Trouble Restore Report (Contact ID Event
Code 300) is sent when the AUX power supply is
reset. The system reports the event approximately 10
sec after power supply is reset.
15.22 System Status – AC Fail Report
Location
Tens digit
Units digit
Location
Default
An AC Fail Report (Contact ID Event Code 301) is
409
7
sent to the base station receiver when the AC
410
13
MAINS supply is disconnected for 2 min. If you do
not want an AC Fail Report to be sent until the AC
MAINS supply is disconnected for 1 hour, select
Option 1 in Location 494 (refer to Section 18.3 System
Options 3 on page 81). If you want to ignore AC Fail,
select Option 2 in Location 494.
15.23 System Status – AC Fail Restore
Location
Tens digit
Units digit
An AC Fail Restore Report is sent when the AC
MAINS supply is connected continuously for longer
than 2 min.
Supply Fail Report
412 to 413
Location
412
413
Supply Fail Restore Report
414 to 415
Location
414
415
416 to 417
Location
416
417
If AC Fail Reports are not required,
program Locations 416 and 417 as 0.
Report
416 to 417
Location
416
417
If AC Fail Restore Reports are not
required, program Locations 418 and 419
as 0.
EN | 68
Default
10
3
Default
10
8
Default
10
2
Default
10
7

Advertisement