Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 7.0
3. Enter [9 6 3 #].
Two beeps sound after the programming key's
data is successfully copied to the control panel. A
long beep indicates that the programming key is
corrupt and must be erased to clear the corrupt
data. Refer to Section 7.4.6 Command 964 – Erase
the Programming Key on page 38 for more
information.
4. Enter [9 6 0 #] to exit from Installer's
Programming Mode.
The STAY and AWAY indicators are
extinguished on the remote codepad to indicate
the system is disarmed.
5. Remove the programming key from the control
panel.
Failure to exit from Installer's Programming
Mode before removing the programming key
can corrupt the programming key.
7.4.6
Command 964 – Erase the
Programming Key
This command erases all data from the programming
key. You can only use the CC891 Programming Key
with the ICP-CC488 Control Panel.
To erase the programming key:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad displays the data
stored in Location 000.
2. Connect the programming key to the
PROGRAMMING KEY pins (next to the
Auxiliary Module socket) at the top of the
control panel found printed circuit board.
3. Enter [9 6 4 #].
Two beeps sound after the data is deleted.
4. Enter [9 6 0 #] to exit from Installer's
Programming Mode.
The STAY and AWAY indicators are
extinguished on the remote codepad to indicate
the system is disarmed.
5. Remove the programming key from the control
panel.
Failure to exit from Installer's Programming
Mode before removing the programming key
can corrupt the programming key.
7.4.7
Command 965 – Set Up Domestic
Dialing Format
Command 965 simplifies the setup of the domestic
dialing format to a one-step operation. Refer to
Section 9.0 Domestic Dialing on page 42 for more
information.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Programming
To set up domestic dialing format:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad displays the data
stored in Location 000.
2. Enter [9 6 5 #].
The command automatically sets Receiver 1 to
domestic reporting and sets the locations shown
in bold in Table 37 on page 39 for Receiver 2
only. No other locations are changed when you
issue command 965.
All domestic telephone numbers are stored in
Locations 550 to 597. For more information, refer to
Section 9.2 Setting Up and Programming Domestic
Reporting on page 43.
As shown in Table 37 on page 39, the transmission
format is automatically set for domestic dialing and
the Subscriber ID Number set for one identification
beep. All reports, except Zone Status reporting and
System Status reporting, are allocated to Receiver 1
for domestic dialing.
Zone Status Reports including Zone Bypass, Zone
Trouble, Sensor Watch, and Alarm Restore codes,
and System Status Reports including AUX Power
Supply Fail, AC Fail, Low Battery, and Access
Denied Reports are allocated to Receiver 2 and do
not report unless Receiver 2 is also set up to report.
7.4.8
Command 966 – Enable/Disable the
Automatic Stepping of Locations
This command allows the automatic stepping of
locations when programming in Installer's
Programming Mode.
Programming with the remote codepad provides no
visual indication that Auto Step Mode is enabled.
To enable the automatic stepping of locations:
1. Enter the Installer Code (default = 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad displays the data
stored in Location 000.
2. Enter [9 6 6 #].
Two beeps sound.
To disable the automatic stepping of locations:
Enter [9 6 6 #].
Two beeps sound.