Zone Allocations for Areas 1 and 2

502 to 517
Location
Zone 1 LED – Area 1 Codepad
Zone 2 LED – Area 1 Codepad
Zone 3 LED – Area 1 Codepad
Zone 4 LED – Area 1 Codepad
Zone 5 LED – Area 1 Codepad
Zone 6 LED – Area 1 Codepad
Zone 7 LED – Area 1 Codepad
Zone 8 LED – Area 1 Codepad
Zone 1 LED – Area 2 Codepad
Zone 2 LED – Area 2 Codepad
Zone 3 LED – Area 2 Codepad
Zone 4 LED – Area 2 Codepad
Zone 5 LED – Area 2 Codepad
Zone 6 LED – Area 2 Codepad
Zone 7 LED – Area 2 Codepad
Zone 8 LED – Area 2 Codepad
0
Not mapped for this LED
1
A zone is mapped to this LED
You can enable or disable the zone allocations for
Area 1 and Area 2. For example, if the location 507
is set to "0", the zone LED of Area 1 is not mapped.
Detailed Example
In the following example, Zones 1, 2, 3, and 4 are
allocated to Area 1 to appear as zones 1, 2, 3 and 4.
Zones 1, 5, 6, 7, 8 are allocated to Area 2 to appear
as zones 1, 5, 6, 7, and 8. Programming the same
zone into more than one area specifies that zone as a
common zone.
Figure 18: Area 1 Codepad Display
Area 1 Zone Allocations
Locations 502 to 509: 1 2 3 4 0 0 0 0
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Partitioning
Figure 19: Area 2 Codepad Display
Location
Default
502
0
503
0
504
0
505
0
506
0
507
0
508
0
509
0
510
0
511
0
Area 2 Zone Allocations
512
0
Locations 510 to 517: 1 0 0 0 5 6 7 8
513
0
514
0
19.5
515
0
516
0
Location
517
0
User Code 1
User Code 2
User Code 3
User Code 4
User Code 5
User Code 6
User Code 7
User Code 8
User Code 9
User Code 10
User Code 11
User Code 12
User Code 13
User Code 14
User Code 15
User Code 16
Locations 534 to 549 are used to assign each User
Code to one or two area areas of a partitioned ICP-
CC488 Control Panel. Enter a value from 0 to 3 into
each of these locations to assign the User Code
holder to the areas it must operate (refer to Table 61).
You can allocate multiple User Codes to the same
area.

Table 61: User Code Allocations

Option
0
1
2
3
19.6
Only the CP5 Area Addressable (CP500A) and CP5
Master Partitioned (CP500P) codepads can be used
with a partitioned ICP-CC488 Control Panel.

User Code Allocations

534 to 549
Location
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
Description
Not allocated to an area
Allocated to Area 1
Allocated to Area 2
Allocated to Area 1 and Area 2
Setting Up and Programming
Codepads for Partitioning
EN | 86
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Advertisement