Walk Test Mode; Event Memory Recall Mode; Telephone Monitor Mode Indications.26 Event Sequence; Event Memory Playback - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 5.0
Table 23: Telephone Monitor Mode Indications
Zone LED
Dialing Event
1
Telephone line seized
2
Dialing phone number
3
Handshake received
4
Data is being transmitted
5
Kiss-off received
None
Telephone line released
To turn Telephone Monitor Mode on:
1. Enter the Installer Code and press [6][AWAY].
Three beeps sound.
2. Press and hold [9] until two beeps sound.
A Test Report is sent.
To turn Telephone Monitor Mode off:
Enter the Installer Code and press [6][AWAY].
Two beeps sound.
You must exit from Telephone Monitor
Mode to resume normal operations.
5.1.8

Walk Test Mode

Walk Test Mode allows you to test detection devices
to ensure they are functioning correctly. Before
activating Walk Test Mode, isolate any zones that are
not required for testing. Refer to Section 3.11 Isolating
Zones for more information. Use Locations 383 and
384 to enable Walk Test Mode Reports (refer to
Section 15.2).
To enter Walk Test Mode:
1. Enter the Installer Code and press [7][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash. The codepad beeps once per sec
when Walk Test Mode is active.
2. Unseal and seal the zones to be tested.
The codepad sounds one long beep and the horn
speaker sounds one short beep each time a zone
is sealed or unsealed.
3. Press [AWAY] to exit from this function.
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns
to the disarmed state.
5.1.9

Event Memory Recall Mode

This function allows you to play back the last 40
system events that occurred. Event Memory Recall
Mode reports all alarms and each arming or
disarming of the system and helps with
troubleshooting system faults. The events are
displayed using the codepad indicators.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Functions
To enter Event Memory Recall Mode:
Enter the Installer Code and press [8][AWAY].
Three beeps sound. The events are played back by
the codepad indicators in reverse chronological
order.
Example
If the events occurred in the following order:
Table 24: Event Sequence
Sequence
Event
1
System armed in AWAY Mode
2
Alarm in Zone 3
3
Alarm in Zone 4
4
System disarmed
The alarm memory plays back in this order:
Table 25: Event Memory Playback
Sequence
Indication
1
All indicators off
except MAINS
2
Zone 4 and AWAY
indicators light
3
Zone 3 and AWAY
indicators light
4
AWAY indicator
lights
Each event is indicated by a beep and a lit indicator.
Resetting a disarmed 24-Hour Alarm is indicated by
a beep only.
After the last event, three beeps sound to indicate the
end of playback. You can stop the replay at any time
by pressing [AWAY].
If the system is armed in STAY Mode 1 or
STAY Mode 2, the STAY indicator shows
the event memory playback. There is no
differentiation between STAY Mode 1
and STAY Mode 2.
If the control panel is powered down, the
memory of all events is saved.
If a ICP-CC488 Control Panel is
partitioned, only ten events per area play
back.
EN | 26
Event
System disarmed
Alarm in Zone 4
Alarm in Zone 3
System armed in
AWAY Mode

Advertisement

Table of Contents
loading

Table of Contents