AMAX panel 2000 / AMAX panel 2000 EN
8.5.2

Exit Time

You can program Exit Time from 0 to 255 sec in increments of 1 sec. When arming the system
in AWAY Mode, the remote keypad beeps during Exit Time until the final 10 sec, when the
keypad sounds one continuous beep to indicate the end of Exit Time is near.
8.5.3

Keypad Lockout Time

All keypads are locked out for the programmed time if an invalid code is entered more times
than allowed by the code retry attempts programmed in Location 179. The keypad lockout
time is programmed as 3 minutes.
8.5.4

System Power Up Wait Time

The system will not operate zone detection in one minute after the system is powered up for
the Installer to finish the installation.
8.5.5

AC MAINS Fail Wait Time

The AC MAINS Fault report is sent out with other fault reports or one hour delayed.
8.6

Optional Equipment

BOSCH Group manufactures a number of accessories that can be used in conjunction with
the AMAX panel 2000 / AMAX panel 2000 EN Control Panel. These optional pieces of
equipment enhance certain features to make the system extremely flexible.
8.6.1

RE012 E 2-Channel Hand-Held Keyfob 433 MHz

This hand-held radio keyfob RE012/E operates the system remotely. Cooperating with
WE800E, the keyfob can remotely arm and disarm the system .
8.6.2

WE800E 433 MHz RF Receiver

This interface allolws the use of up to eight radio User Codes (9 - 16). This is useful if you
want the system to be radio controlled and you would like to give your customer total control
using a radio hand-held remote transmitter.
8.6.3

ICP-EZPK Programming Key

The programming key copies and stores all information programmed in your control panel.
The programming key can hold all your common configuration data such as monitoring station
telephone numbers and zone reporting channels.
8.6.4

A-Link Plus Software

This A-Link Plus software package is designed to program the AMAX panel 2000 / AMAX panel
2000 EN Control Panel by remote connect methods. This software can access all options and
features and in addition to maintaining history and service reports. Program options to use
this feature in Location 153. Refer to Section 7.4 Software, page 49for more information.
8.6.5

DX3010 8 Relay Module

Eight programmable relay outputs provided by this module.Set in Location 150 to use DX3010
as below:
Bosch Sicherheitssysteme GmbH
Installation Manual
System Informations 2 | en
F.01U.241.127 | V4 | 2011.12