Change Telco Arm/Disarm Sequence; Codepad Indicators When Changing Phone Numbers; Telco Arm/Disarm Dialing Digits - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 5.0
Table 21: Codepad Indicators When Changing
Phone Numbers
Zone Indicators
Digit
1
2
3
4
0
1
X
2
X
3
X
4
X
5
6
7
8
9
X
*
X
#
X
Pause
X
Break
X
15
5.1.4

Change Telco Arm/Disarm Sequence

This function allows you to program the call forward
sequence to automatically operate when you arm the
system in AWAY Mode. This feature is available
only if the call forward option is available from your
telecommunication provider.
Telco Arm Sequence
This option allows you to program the Call Forward
– Immediate On sequence or Call Forward – No
Answer sequence that automatically operates when
you arm the system in the AWAY Mode..
The examples provided for this feature
apply only to Australia.
Call Forward – Immediate On
You can redirect calls to anywhere in Australia,
including mobiles, pagers, and answering
services. When this Call Forward option is
turned on, your telephone does not ring.
Call Forward – No Answer
If your telephone is not answered within 20 sec,
this feature redirects the incoming call to another
number anywhere in Australia. You can still
make outgoing calls.
Telco Disarming Sequence
This option allows you to automatically disable the
call forward sequence when you disarm the system.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Functions
MAINS
5
6
7
8
Indicator
X
X
X
X
X
X
X
X
X
X
X
X
Table 22: Telco Arm/Disarm Dialing Digits
Digit
Number to
Required
Program
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
To program the telco arming sequence:
1. Enter the Installer Code and press [3][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Press [1][AWAY] to change the telco arming
sequence. Three beeps sound.
If a call forwarding sequence is already
programmed, the sequence is displayed one digit
at a time using the remote codepad indicators.
Refer to Table 21 on page 24 for the indicators
and their meanings.
If no call forward sequence is programmed, an
additional two beeps sound after entering this
mode. These two beeps normally sound after the
last digit of the call forward sequence is
displayed.
3. Enter the desired call forward sequence.
For example, program [* 6 1][phone number][#]
for the call forward – no answer sequence, or [* 2
1][phone number][#] for the call forward –
immediate sequence.
Remember that when you program a * in
the telco arm sequence, you enter
[STAY][1]. When you program the # in
the telco arm sequence, you enter
[STAY][2].
4. Press [STAY][2][AWAY].
Two beeps sound and the system returns to the
disarmed state.
Example
If you want to automatically divert all unanswered
incoming calls to another telephone number (for
example, 9672 1777) when the system is armed in
AWAY Mode, enter:
[1 2 3 4 3][AWAY][1][AWAY][STAY]
[1 6 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]
You can suspend the telco arming sequence at any
time. To disable the telco arming sequence:
Enter the Installer Code and press [3][AWAY][1]
[AWAY][STAY][4][AWAY].