4 – Strobe Indications for Radio Arm/Disarm
This option allows the strobe to indicate when the
system is armed and disarmed when remotely
operating the system using the DSRF Series RF
Receiver.
Table 60: Strobe Indications for Remote
Operations
Strobe Duration
3 sec
6 sec
6 sec
8 – Assign Button 4 To Operate STAY Mode 4
This option allows Button 4 on the RF3334
4 Channel Hand Held Transmitter to arm the system
in STAY Mode 1.
18.2

System Options 2

Location
493
Default
0
1
Codepad Panic to be silent
2
Codepad Fire to be silent
4
Codepad Medical to be silent
8
Access denied (code retries) to be silent
1 – Codepad Panic To Be Silent
If this option is selected, a Codepad Panic Alarm or
Radio Remote Panic Alarm does not operate the
horn speaker, the bell, or the strobe outputs. If this
option is not selected, all three outputs operate after a
Codepad Panic Alarm is activated when a user
presses [1] and [3] or [STAY] and [AWAY] at the
same time on the remote codepad. Selecting this
option does not affect the operation of the
communication dialer.
If you want to disable reporting of a Codepad Panic
Alarm, program Locations 404 and 405 as 0 (refer to
Section 15.16 Codepad Panic Report on page 66).
2 – Codepad Fire To Be Silent
If this option is selected, a Codepad Fire Alarm does
not operate the horn speaker, the bell, or the strobe
outputs. If this option is not selected, all three outputs
operate after a Codepad Fire Alarm is activated
when a user presses [4] and [6] at the same time on
the remote codepad. Selecting this option does not
affect the operation of the communication dialer.
If you want to disable the reporting of a Codepad
Fire Alarm, program Locations 407 and 408 as 0
(refer to Section 15.17 Codepad Fire Report on page 66).
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Status
System disarmed
System armed in AWAY Mode
System armed in STAY Mode 1
System and Consumer Options
4 – Codepad Medical To Be Silent
If this option is selected, a Codepad Medical Alarm
does not operate the horn speaker, the bell, or the
strobe outputs. If this option is not selected, all three
outputs operate after a Codepad Medical Alarm is
activated when a user presses [7] and [9] at the same
time on the remote codepad. Selecting this option
does not affect the operation of the communication
dialer.
If you want to disable the reporting of a Codepad
Medical Alarm, program Locations 409 and 410 as 0
(refer to Section 15.18 Codepad Medical Report on page
68).
8 – Access Denied (Code Retries) To Be Silent
If this option is selected, a Codepad Tamper Alarm
does not operate the horn speaker, bell, or the strobe
outputs. If this option is not selected, all three outputs
operate after a Codepad Tamper Alarm occurs.
Refer to Section 15.26 System Status – Access Denied on
page 69 to set the number of invalid code retries that
causes an alarm condition. Selecting this option does
not affect the operation of the communication dialer.
If you want to disable the reporting of Access Denied
reports, program Locations 424 to 426 as 0.
18.3

System Options 3

Location
494
1
AC fail after 1 hour (disabled – after 2 min)
2
Ignore AC fail
4
Pulse count handover allowed
8
Handover delay to be sequential
1 – AC Fail after 1 Hour
If this option is selected, the MAINS indicator flashes
when the AC MAINS supply is disconnected. An AC
Loss signal (Contact ID Event Code 301) is
transmitted to the base station receiver after the AC
MAINS supply is disconnected continuously for
longer than 60 min.
If this option is not selected, the MAINS indicator
flashes and an AC Loss signal (Contact ID Event
Code 301) is transmitted to the base station receiver
after the AC MAINS power is disconnected
continuously for 2 min.
The MAINS indicator stops flashing when the AC
MAINS supply is restored longer than 2 min.
An AC Loss Restore Report is transmitted to the
base station receiver after the AC MAINS supply is
restored continuously for more than 2 min regardless
of whether this option is selected.
EN | 81