ICP-CC488 | Installation Guide | 2.0
Section 3.5 to arm the system in STAY Mode 2.
Section 5.1.5 to use the Installer Code to set zones
to be automatically isolated in STAY Mode 2.
Section 5.2.6 to use the Master Code to set zones
to be automatically isolated in STAY Mode 2.
System Disarmed
This indicator lights with the OFF
indicator when the system is disarmed.

MAINS Indicator

The MAINS indicator displays whether
the systems AC MAINS supply is
normal or failed.
When programming in Installer's Programming
Mode or using a Master Code function, the MAINS
indicator lights to indicate a location value from 10 to
15. The MAINS indicator represents the 10 digit,
which is added to the value of the lit zone indicator
(for example, if the value programmed in a location
is 12, the MAINS and Zone 2 indicators light).
Table 9:
MAINS Indicator
Indicator
Definition
On
The AC MAINS power normal.
Flashing
The AC MAINS supply failed.
FAULT indicator
The FAULT indicator lights when the
system detects a system fault (refer to
Table 7 on page 11). Refer to Section 3.12
Fault Analysis Mode on page 18 for more
information on system faults.
Each time a new system fault is detected (the FAULT
indicator flashes), the codepad beeps once per min.
Press [AWAY] to stop the beeping and acknowledge
the fault.
Programming Mode
These two indicators flash when you
enter Installer's Programming Mode or
use any Master Code function.
Flashing
OFF Indicator/Zone Sealed
The OFF indicator lights when the
system is disarmed and flashes when a
zone becomes unsealed when disarmed.
The indicator stops flashing when all
zones are sealed.
ON Indicator/Zone in Alarm
The ON indicator lights when the
system is armed and flashes when an
alarm occurs. The indicator is reset after
a valid User Code is entered.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Codepad Indicators
Audible Indicators
The codepad provides a number of audible
indications. Refer to Table 8 on page 11.
2.3
ICP-CP500PW Master Partitioned
LED Codepad
Figure 3:
ICP-CP500PW Master Partitioned

Codepad

This codepad is used only on a partitioned
ICP-CC488 Control Panel. The Master Partitioned
LED codepad allows a user to operate both areas
individually from the same codepad, without the
need to operate individual areas from separate
codepads.
The codepad is the communications interface
between you and the alarm system. The codepad
allows you to issue commands and offers visual and
audible indications to guide you through general
operation.
The codepad incorporates a number of indicators:
eight zone indicators show the condition of each
zone, eight area indicators show the area status, and
four other indicators show general status. These
indicators are described in the tables throughout this
section.
Zone Indicators
The zone indicators (1 to 8) show the status of each
zone as defined in Table 3 on page 10. The zones
belong to the area with the lit Area Display indicator.
AREA ON/OFF Indicators
The group of four Area On/Off indicators shows the
status of each area as defined in Table 10 on page 13.
If an area is armed in STAY Mode 1, the
corresponding Area On/Off indicator is lit in
conjunction with the PARTIAL indicator. If the area
is armed in AWAY Mode, only the ON/OFF
indicator is lit.
EN | 12