Figure 21: Connections for CP-5 Master
Partitioned Codepad and CP-5 Area
Addressable Codepad
1 – Data
2 – CLK
3 – +12 V
4 – GND
Set the DIP Switches and program these locations for
the two CP-5 Area Addressable (CP500A) codepads
to function correctly.
1. Set DIP Switch 1 on the back of the remote
codepad for Area 1 to the ON position (refer to
Figure 20 on page 87).
2. Set DIP Switch 2 on the back of the remote
codepad for Area 2 to the ON position.
3. Select Option 2 in Location 500 (refer to Section
19.3.1 Partitioning Options 1 on page 85).
4. For Output 1, program Location 436 to 6 and
Location 437 to 1 (refer to page 75).
Bosch Security Systems, Inc. | 12/08 | F01U089457-02

RF Information

5 – Master Partitioned

Codepad

6 – Addressable Area
Codepad
Figure 22: Connections for Two CP-5 Area

Addressable Codepads

1 – Data
2 – CLK
3 – +12 V
20.0 RF Information
20.1

RF Option Bit

Location
599
Default
0
1
Sound siren on RF receiver fail
2
Sound siren on RF receiver tamper/jamming
4
Unseal zone that fails supervision (if supervision
enabled)
8
Enable RF jamming monitoring
1 – Sound Siren on RF Receiver Fail
If this option is selected, the horn speaker, piezo, and
strobe operate when the RF receiver fails to
communicate with the control panel.
2 – Sound Siren on RF Tamper/Jamming
If this option is selected, the horn speaker, piezo, and
strobe operate when the tamper switch on the
receiver becomes open circuit or the receiver picks
up jamming signals from an RF device.
4 – Unseal Zone that Fails Supervision
If a wireless zone device fails to send a signal within
the RF Supervision Time programmed in Location
393 (refer to Section 15.8) the codepad zone indicator
lights as unsealed.
EN | 88
4 – GND
5 – Area 1 Codepad
6 – Area 2 Codepad