Bosch ICP-CC488 Installation Manual page 104

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 25.0
Zones
267 to 378
Location
Zone 1
Default
Zone 2
Default
Zone 3
Default
Zone 4
Default
Zone 5
Default
Zone 6
Default
Zone 7
Default
Zone 8
Default
Zone 9
Default
Zone 10
Default
Zone 11
Default
Zone 12
Default
Zone 13
Default
Zone 14
Default
Zone 15
Default
Zone 16
Default
Each zone contains seven locations. The first three
locations determine how the zone operates:
Zone Type
Zone Pulse
Count
The next two locations contain zone options:
Zone Options 1
The last two locations contain reporting information:
Report Code
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Programming Sheets
Zone Types
Refer to page 58
These are the zone types available:
Locations 267 to 273
2 0 0 1 14 1 1
Locations 274 to 280
1 0 0 1 14 1 1
Locations 281 to 287
1 0 0 1 14 1 1
Locations 288 to 294
1 0 0 1 14 1 1
Locations 295 to 301
0 0 0 1 14 1 1
Locations 302 to 308
0 0 0 1 14 1 1
Locations 309 to 315
0 0 0 1 12 1 1
Locations 316 to 322
9 0 0 1 12 1 1
Locations 323 to 329
15 0 0 1 14 1 1
Zone Pulse Count Settings
Locations 330 to 336
Program the pulse count settings for each zone from
15 0 0 1 14 1 1
0 to 15.
Locations 337 to 343
Zone Pulse Count Time
15 0 0 1 14 1 1
Zone pulse count time is the time frame or period
Locations 344 to 350
over which the number of pulses must register.
15 0 0 1 14 1 1
Locations 351 to 357
20 ms Loop Response
15 0 0 1 14 1 1
Option
Locations 358 to 364
0
15 0 0 1 14 1 1
1
Locations 365 to 371
2
15 0 0 1 14 1 1
3
Locations 372 to 378
4
15 0 0 1 14 1 1
5
6
7
Zone Options 1
Zone Pulse
Count Time
Option
1
2
Zone Options 2
4
8
Zone Options 2
Dialer Options
Option
1
2
4
8
Zone Type
Description
0
Instant
1
Handover
2
Delay-1
3
Delay-2
4
Reserved
5
Reserved
6
24-Hour Medical
7
24-Hour Panic
8
24-Hour Holdup
9
24-Hour Tamper
10
Reserved
11
Keyswitch
12
24-Hour Burglary
13
24-Hour Fire
14
Chime only
15
Zone not used
150 ms Loop Response
Time (sec)
Option
0.5
8
1
9
2
10
3
11
4
12
5
13
10
14
15
15
Description
Lockout siren/lockout dialer
Delay alarm reporting
Silent alarm
Sensor watch
Description
Isolated in STAY Mode 1
Zone isolation allowed
Forced arming allowed
Enable Zone Restore Report
EN | 104
Time (sec)
20
30
40
50
60
90
120
200

Advertisement

Table of Contents
loading

Table of Contents