Arming The System In Stay Mode 2 - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 3.0
To arm the system in STAY Mode 1 (method
one):
1. Enter your code and press [STAY].
2. Two beeps sound and the STAY indicator is lit.
Exit Time starts.
The indicators for any zones that are programmed to
be automatically isolated in STAY Mode 1 begin to
flash until Exit Time expires. At the end of Exit
Time, the zone indicators are extinguished and the
codepad sounds one short beep.
To arm the system in STAY Mode 1 (method
two):
1. Press and hold [STAY].
2. When two beeps sound, release the button.
The STAY indicator is lit and Exit Time starts.
The indicators for any zones that are programmed to
be automatically isolated in STAY Mode 1 flash until
Exit Time expires. At the end of Exit Time, the zone
indicators are extinguished and the codepad sounds
one short beep.
If a zone is not sealed at the end of Exit Time, the
zone is automatically isolated and is lit constantly on
the remote codepad. The zone becomes an active
part of the system again as soon as it is resealed. For
example, if a window is open when Exit Time
expires, the window does not become an active part
of the system until it is closed. Opening the window
after Exit Time expires causes an alarm.
Forced Arming
Arming the system when a zone is not sealed is
known as forced arming. Refer to Section 14.3.7 Zone
Options 2 on page 63 to enable forced arming for
each zone.
If the STAY indicator does not light and a long beep
sounds when you attempt to arm the system in STAY
Mode 1, forced arming is not permitted. If this is the
case, you must seal all zones or manually isolate
them before you can arm the system.
3.4
Disarming the System from STAY
Mode 1
There are two methods to disarm the system from
STAY Mode 1. You can always use the first method.
You can use method two only if Option 4 is enabled
in Location 497 (refer to Section 18.6 Consumer
Options 2 on page 83).
To disarm the system from STAY Mode 1
(method one):
1. Enter your code and press [STAY].
2. Two beeps sound and the STAY indicator is
extinguished. The system is now disarmed.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Operations
To disarm the system from STAY Mode 1
(method two):
A flashing zone indicator represents a previous alarm
in that zone. If this is the case, a valid User Code is
required to disarm the system using method one. To
enable method two, Option 4 in Location 497 must
be enabled (refer to Section 18.6 Consumer Options 2 on
page 83).
1. Press and hold [STAY].
2. When two beeps sound, release the button.
The STAY indicator is extinguished and the
system is disarmed.
Single button disarming from STAY
Mode 1 reports as User Code 16.
3.5
Arming The System in STAY Mode
2
STAY Mode 2 is used when you need to arm the
perimeter and unused areas of the premises to detect
a would-be intruder from entering the premises,
while at the same time being able to move freely
within an area that is automatically isolated.
You can program zones to be automatically isolated
in STAY Mode 2 using an Installer Code function
(refer to Section 5.1.5) or a Master Code function
(Section 5.2.6).
If the system reports to a base station, it sends a
Partial Close Report (Contact ID Event Code 456).
Entry Guard Timer for STAY Mode
When arming the system in STAY Mode 2, an
optional entry timer called Entry Guard Timer for
STAY Mode can be used to delay the sirens, strobe,
and bell outputs if a zone that is not automatically
isolated activates an alarm. Entry Guard Timer for
STAY Mode is the delay time used for all zones,
except 24-Hour zones, when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode is
programmed and a zone that was not automatically
isolated is activated, the codepad beeps twice per sec
until the Entry Guard Timer for STAY Mode expires
or the system is disarmed. If the alarm is not reset
before Entry Guard Timer for STAY Mode expires,
the strobe, bell, and siren outputs are activated into
alarm.
Single button disarming from STAY
Mode 2 reports as User Code 16.
To arm the system in STAY Mode 2:
1. Press and hold [0].
2. When two beeps sound, release the button.
The STAY indicator is lit and the Exit Time
starts.
EN | 15

Advertisement

Table of Contents
loading

Table of Contents