Programming Option Bits; Installer's Programming Commands; Command 959 - Test The Programming Key; Programming Option Bits Example - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 7.0
If you do not enter Installer's Programming
Mode first, connecting the CC891
Programming Key to the control panel
when the programming key memory is
blank corrupts the control panel's
memory. If this occurs, you must return
the control panel to Bosch Security
Systems, Inc. to unlock the control panel's
memory. A service fee will be charged.
7.3

Programming Option Bits

When programming these locations, each location
has four options. You can select one, two, three, or
all four options for each location, but you can
program only one value for the location. Calculate
this value by adding the option bit numbers together.
Example
If you want to select Options 1, 2, and 4 for Location
177, add the numbers and program the sum. In this
example, program a 7 in the location (1 + 2 + 4 = 7).
Table 35: Programming Option Bits Example
Option
Description
1
Allow dialer reporting functions
2
Enable remote arming by telephone
4
Enable answering machine bypass only when
armed
8
Enabled = Use Bell 103 for FSK format
Disabled = CCITT V21 format
7.4
Installer's Programming
Commands
You can use ten commands in Installer's
Programming Mode. To issue the command, enter
the command number and press [#].
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Programming
Table 36: Installer's Programming Mode
Commands
Command
Function
959
Test the programming key
Refer to Section 7.4.1.
960
Exit from Installer's Programming Mode
Refer to Section 7.4.2.
961
Reset the control panel to factory defaults
Refer to Section 7.4.3.
962
Copy the control panel memory to the
programming key
Refer to Section 7.4.4.
963
Copy the programming key data to the
control panel memory
Refer to Section 7.4.5.
964
Erase the programming key
Refer to Section 7.4.6.
965
Set up domestic dialing format
Refer to Section 7.4.7.
966
Enable/disable the automatic stepping of
locations during programming
Refer to Section 7.4.8.
999
Display the software version number or
control panel type
Refer to Section 7.4.9.
7.4.1
Command 959 – Test the Programming
Key
This command initiates a test of the programming
key. You can use the CC891 Programming Key only
with the ICP-CC488 Control Panel.
The programming key test is non-destructive, and
any data in the programming key remains after the
test is completed. One long beep indicates that the
programming key test failed. Two beeps indicates a
successful test.
If you remove the programming key before the test is
finished, the programming key data becomes corrupt.
Do not remove the programming key while the
activity LED is lit or pulsing rapidly.
To test the programming key:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad displays the data
stored in Location 000.
2. Connect the programming key to the
PROGRAMMING KEY pins (next to the
Auxiliary Module socket) at the top of the
control panel printed circuit board.
EN | 36