Setting Up The Master Partitioned Codepad As The Main Codepad; Setting Up An Area 1 Codepad As The Main Codepad; Setting Up An Area 1 Codepad; Setting Up An Area 2 Codepad - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents

Advertisement

ICP-CC488 | Installation Guide | 19.0
19.6.1
Setting Up the Master Partitioned
Codepad as the Main Codepad
To use the CP5 Master Partitioned (CP500P)
codepad as the main codepad in a partitioned
system, connect the codepad to the main codepad
terminals (CP-, CP+, CLK, and DATA). Set all DIP
switches on the back of the codepad to the ON
position (refer to Figure 20 on page 87).
19.6.2
Setting Up an Area 1 Codepad as the
Main Codepad
If you are not using the CP5 Master Partitioned
codepad as the main codepad of the partitioned
system, connect the Area 1 codepad to the main
codepad terminals (CP-, CP+, CLK, and DATA). Set
DIP switch 1 on the back of the codepad into the ON
position (refer to Figure 20 on page 87) and select
Option 2 in Location 500 (refer to Section 19.3.1
Partitioning Options 1 on page 85).
19.6.3

Setting Up an Area 1 Codepad

If you want a separate area codepad only for Area 1
when using the CP5 Master Partitioned codepad as
the main codepad, connect the Area 1 codepad to
the main codepad terminals (CP-, CP+, and CLK)
and connect the DATA terminal to one of the
outputs programmed as 6,0 Area 1 Codepad Data
(refer to page 75). Set DIP switch 1 on the back of the
Area 1 codepad to the ON position (refer to Figure 20
on page 87).
19.6.4

Setting Up an Area 2 Codepad

If you want a separate area codepad only for Area 2,
connect the Area 2 Codepad to the main codepad
terminals (CP-, CP+, and CLK) and connect the
DATA terminal to one of the outputs programmed as
6,1 Area 2 Codepad Data (refer to page 75). Set DIP
switch 2 on the back of the Area 2 codepad to the
ON position (refer to Figure 20 on page 87).
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Partitioning
Figure 20: DIP Switch Location on Codepad
1 – DIP Switches
19.7
Codepad Connections For
Partitioning - Examples
If the CP-5 Area Addressable (CP500A) codepad is
assigned to Area 1:
1. Set DIP Switch 1 on the back of the remote
codepad to the ON position (refer to Figure 20 on
page 87).
2. For Output 1, program Location 436 to 6 and
Location 437 to 0 (refer to page 75).
If the CP-5 Area Addressable (CP500A) codepad is
assigned to Area 2:
1. Set DIP Switch 2 on the back of the remote
codepad to the ON position. (refer to Figure 20
on page 87).
2. For Output 1, program Location 436 to 6 and
Location 437 to 1 (refer to page 75).
EN | 87