ICP-CC488 | Installation Guide | 2.0

MAINS Indicator

The MAINS indicator displays whether the system's
AC MAINS supply is normal or failed.
When programming in Installer's Programming
Mode or using a Master Code function, the MAINS
indicator lights to indicate a location value from 10 to
15. The MAINS indicator represents the 10 digit,
which is added to the value of the lit zone indicator
(for example, if the value programmed in a location
is 12, the MAINS and Zone 2 indicators light).
Table 6:
MAINS Indicator
Indicator
Definition
On
The AC MAINS power is normal.
Flashing
The AC MAINS supply failed.

FAULT indicator

The FAULT indicator lights when the system detects
a system fault. Refer to Section 3.12 Fault Analysis
Mode on page 18 for more information on system
faults.
Each time a new system fault is detected (the FAULT
indicator flashes), the codepad beeps once per min.
Press [AWAY] to stop the beeping and to
acknowledge the fault.
Table 7:
FAULT indicator
Indicator
Definition
On
A system fault must be corrected.
Off
The system is normal (no faults).
Flashing
A system fault must be acknowledged.

Audible Indicators

The codepad provides these audible indications:
Table 8:
Audible Indicators
Audible Indicator
Definition
One short beep
A button was pressed on the
codepad, or Exit Time ended when
arming in STAY Mode 1 or STAY
Mode 2.
Two short beeps
The system accepted your code.
Three short beeps
The system executed the requested
function.
One long beep
Exit Time ended when arming in
AWAY Mode, or the requested
operation was denied or aborted.
One short beep
Walk Test Mode is currently active,
every sec
or warning before automatic arming
takes place.
One short beep
Telephone Monitor Mode is active.
every 2 sec
One short beep
There is a system fault to be
every min
acknowledged.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Codepad Indicators
2.2
ICP-CP508LW Eight Zone LCD

Codepad

Figure 2:
ICP-CP508LW Eight Zone LCD
Codepad
The codepad is the communications interface
between you and the alarm system. The codepad
allows you to issue commands and offers visual and
audible indications to guide you through general
operation.
The codepad incorporates a number of indicators:
eight zone indicators show the condition of each zone
and seven other indicators show general status. These
indicators are described in the tables throughout this
section.
Zone Indicators
The zone indicators (1 to 8) display the
1 2 3 ...
status of the zones listed in Table 3 on
page 10.
AWAY Indicator
The AWAY indicator lights when the
system is armed in AWAY Mode. The
ON indicator also lights when the
system is armed in AWAY Mode
(refer to Table 5 on page 10).
The AWAY indicator flashes with the STAY
indicator when you are in Installer's Programming
Mode or you are using a Master Code function.
Refer to Section 3.1 Arming the System in AWAY Mode
for more information.
STAY Indicator
The STAY indicator lights when the
system is armed in STAY Mode 1 or
STAY Mode 2 (refer to Table 4).
The STAY indicator also flashes with the AWAY
indicator when you are in Installer's Programming
Mode or you are using a Master Code function.
The ON indicator also lights when the system is
armed in STAY Mode 1 or STAY Mode 2.
For more information, refer to:
Section 3.3 to arm the system in STAY Mode 1.
Section 14.3.5 to set zones to be automatically
isolated in STAY Mode 1.
EN | 11